UETDRDU013 – Joint, terminate and maintain high voltage underground polymeric cable

This course is designed to train individuals who are required to hold a current certificate for the specified work.
This course has been tailored based on industry best-practice and to be in accordance with the relevant standards and legislations.
The course will be delivered by an experienced industry professional, bringing a depth of knowledge and experience to the participant.

Through the completion of this course learners will acquire the skills and knowledge required to joint, terminate and maintain high voltage (HV) underground polymeric cable in the electricity supply industry (ESI).

It includes jointing, terminating and the testing of cable in new installations. It also includes maintaining cable in existing installations, including repairing, replacing, re-jointing or re-terminating and testing of de-energised cable.

It includes using a range of tools, equipment, specialised materials and manufacturer’s instructions.

The application of the skills and knowledge described in this unit may require a licence/registration to practice in the workplace.

Duration
5 or 10 days depending on company requirements
Delivery
Trainer led classroom theory and practcials
Location
This training can be delivered:
• At a customers specific site
• At one of RelyOn Australia's approved training facilities
Cost
Contact our Office for details on 1300 15 66 85 or email us on admin.au@relyon.com.

Who should attend

The target participants for this course are employees currently working within the Australian Electricity Supply Industry. This includes employees of network asset owners, contractors and sub-contractors in electricity Generation, Transmission and Distribution.

Those who work on the network must maintain currency of skills and competency in a range of safety and technical competencies. Relevant safety related training programs are often mandated by regulation or industry agreements and documented in state codes of practice.

Most participants will be licensed and trade qualified or hold a Certificate in a related technical discipline. In addition to trade qualifications, the participant groups will have completed a range of electrical and plant safety related training programs related to the roles they hold. Due to the significant safety risks in the industry these employees work within highly proceduralised workplaces with mature workplace safety systems.

Workers in the industry are required to regularly complete workplace safety risk assessment and work planning documentation, and therefore bring a solid foundational understanding of risk assessment and workplace safety documentation concepts and practices to the program.

Course aim

The course is designed to provide the learner with the knowledge and skills to enable them to safely joint, terminate and maintain high voltage underground polymeric cables

Learning outcomes

On successful completion of the course a participant will be able to:

  • Understand and comply with relevant regulations and enterprise procedures
  • Understand and identify the hazards associated with the work activity, site and site equipment
  • Prepare to joint, terminate and testing of cable in new installations using a range of tools, equipment, specialised materials and manufacturer’s instructions.
  • Maintaining cable in existing installations, including repairing, replacing, re-jointing or re-terminating and testing of de-energised cable.
  • Carry out the jointing, terminating and maintenance of de-energised HV underground polymeric cables
  • Complete jointing, terminating and maintenance of de-energised HV underground polymeric cables

Learning activities

Delivery includes:

  • Trainer led classroom presentations
  • Theory assessment
  • Workshop practical exercises and assessment
  • Logbook of workplace activities.

Units of competency

Code Unit
UETDRDU013 Joint, terminate and maintain high voltage underground polymeric cable

Prerequisites

  • UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
  • UEECD0019 Fabricate, assemble and dismantle utilities industry components
  • UEECD0044 Solve problems in multiple path circuits
  • UEECD0046 Solve problems in single path circuits
  • UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications
  • UEEEL0020 Solve problems in low voltage a.c. circuits
  • UEEEL0021 Solve problems in magnetic and electromagnetic devices
  • UETDREL001 Apply environmental requirements
  • UETDREL005 Work safely in the vicinity of live electrical apparatus

Entry requirements

To participate in this course, learners are required to:

  • have current certification in the required prerequisites:

    • UEECD0007 Apply Occupational Health and Safety regulations, codes and practices in the workplace
    • UEECD0019 Fabricate, assemble and dismantle utilities industry components
    • UEECD0044 Solve problems in multiple path circuits
    • UEECD0046 Solve problems in single path circuits
    • UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications
    • UEEEL0020 Solve problems in low voltage a.c. circuits
    • UEEEL0021 Solve problems in magnetic and electromagnetic devices
    • UETDREL001 Apply environmental requirements
    • UETDREL005 Work safely in the vicinity of live electrical apparatus
  • be literate in spoken English and competent in reading, writing, and numeracy.
  • be sufficiently fit to participate.

Language, literacy and numeracy

All students completing training with RelyOn Australia must have sufficient language, literacy and numeracy skills to undertake training and assessment. All training is delivered in English, requiring the ability to read, write and answer verbal question. Basic numeracy skills are required which vary with each course.

Prior to the commencement of training, the trainer will assess language, literacy and numeracy levels, and will provide support as required.

Equipment and PPE

Learners are required to have the following to participate in this course:

  • Personal Protective Equipment (e.g. Hard Hat, Safety Footwear, Approved Hi-Vis Clothing, Safety Glasses)
  • Stationary (e.g. Pen, Pencil, etc.)

Training equipment

For certain parts of this course, the following equipment are required and will be prepared for the learners to use:

  • Cable stands
  • Joint kits
  • Jointing equipment
  • Trenching equipment

Course materials

The following will be provided to learners to complete the course:

  • Course notes: Slide handouts
  • Assessment workbook

Licensing and regulatory information

The application of the skills and knowledge described in this unit may require a licence/registration to practice in the workplace subject to regulations for undertaking of electrical work.
Other conditions may apply under state and territory legislative and regulatory licencing requirements which must be confirmed prior to commencing this unit.
Specific licensing/regulatory requirements relating to this competency, including requirements for refresher training should be obtained from the relevant national/state/territory Work Health and Safety Regulatory Authorities.

Additional information

Before enrolling, participants are expected to download and read the Participant Handbook to gain a comprehensive understanding of training with RelyOn Australia including the following policies and procedures:

  • Privacy
  • Harassment, discrimination and bullying
  • Safety
  • Enrolment
  • Participant support
  • Course delivery
  • Appeals, complaints and grievances
  • Cancellations
  • Contacts

Chat with a Course Advisor

Please leave your details below and one of our course advisors will be in touch as soon as possible.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
White CT Menu Logo